Boiler

Burner for Boiler・Economizer

LND Type Oil Fired Low NOx Burner

A burner with superior characteristics both in low NOx and low particulate emissions. It is widely used for packaged boilers.

Applications
  • Water tube type boilers, fire tube boilers, thermal oil boilers, hot water boilers, power generation boilers
Characteristics
  • Super-low emission of particulates
  • Adaptable to a wide variety of fuels
  • High turndown ratio (TDR)
  • Capable of continuous operation (with additional sub-burners)

LND Type Oil Fired Low NOx Burner

LPCF Type Large Gas Fired Burner for Low Calorie Fuel

A burner designed for perfect combustion of low calorie fuel by making efficient use of excess gas from factory processes.

Applications
  • Water tube boilers, Power generation boilers, Waste heat boilers, Incinerators
Characteristics
  • Perfect combustion of large quantities of low pressure or low calorie gas
  • Superior flame stability
  • Multi-fueling combustion possible
  • Minimum pressure loss in burner

LPCF Type Large Gas Fired Burner for Low Calorie Fuel

LPCF Type Large Gas Fired Burner for Low Calorie Fuel

CGT Type Regenerator for Gas Turbine Exhaust

A unit which regenerates combustion air by utilizing exhaust gas from gas turbine.

Applications
  • Regeneration of exhaust gas from gas turbine
Characteristics
  • Reduced pressure loss of exhaust gas in regenerator
  • Gas and/or oil fuelling
  • Smooth continuous operation with fresh air when tripping of gas turbine occurs
  • Low NOx emission

CGT Type Regenerator for Gas Turbine Exhaust

ULN Type Gas Fired Low NOx Burner

A two stage combustion type burner with ultra low NOx emission rate.

Applications
  • Water tube boilers, Fire tube boilers, Thermal oil burners, Hot water boilers, Power generation boilers
Characteristics
  • Low NOx emission
  • Multi firing of oil and other fuels is possible
  • High turndown ratio
  • Ultra low NOx emission can be achieved by exhaust re-circulation

ULN Type Gas Fired Low NOx Burner

ULN Type Gas Fired Low NOx Burner

ECG Type
Anti-Corrosion Glass Economizer

A complete anti-corrosion waste heat recovery unit. Although this unit was first designed and marketed 15 years ago, it continues to be favored for its trouble free operation.

Applications
  • Heat recovery from exhaust gas and other thermal sources (heat recovery by water)
Characteristics
  • Complete anti-corrosion construction using anti-thermal glass and Teflon
  • Heat recovery from low temperature heat source
  • Reduced pressure loss
  • Water washing in operation
  • Heat recovery from exhaust gas containing dust
  • Flexible selection of heat transfer area
  • Light weight

ECG Type Anti-Corrosion Glass Economizer

Energy Saving Equipment and Maintenance Service for Boil

Instrumentation for Control of Boiler Operation

  • For combustion control in the boiler, both the latest digital control technology and the conventional analog control technology are available.
  • The burner management system has built-in safety features such as state-of-the-art technology for control of O2 supply and NOx emissions and measures to deal with instantaneous blackouts.
  • The unit has been designed for remote operation using a TV monitor and data transmission.

INV-F Type Inverter Control System

  • Can be adapted to turndown ratio of 10:1
  • Superior controllability and safety
  • Capable of additional O2 trimming and inverter of splashing combustion pump.Applicable electric motor capacity: 0.4kw to 150kw

Control panel forburner managemant
Control panel forburner managemant

Inverter Control Panel with Boiler Water Supply Control
Inverter Control Panel
with Boiler Water Supply Control

Energy Saving Equipment for Boiler

Equipment for Waste Heat Recovery

The company designs and offers systems to meet the needs of clients.

  • Heat recovery source : combustion gas and waste water, air and steam
  • Element Type : Bare tubes and finned tubes
  • Material : STB,SUS-316L and others

Air Heater
Air Heater

DEKA-APH

The DEKA Air Pre-Heater, supplied by By-cast AB, Belgium, has been used world-wide for over 50 years for its superior characteristics - air tightness, anti-corrosion quality, easy maintenance and high-reliability.

DEKA-APH
DEKA-APH

Miscellaneous Equipment for Boilers and Burners

  • Low NOx emission system
  • Low NOx burner(EGR.SI)
  • Improved combustion efficiency and reduction of CO2 emission
  • Can be used with any type of fuel
  • Boiler water supply control system : single, double or triple element control system
  • Load balance control system for water tube boilers, fire tube boilers and once through boilers
  • Improvement of incinerator and combustion furnace

Repair and new construction of stack
Repair and new construction of stack

Test Operation and After Service

  • NFK's team of well-trained and experienced engineers are available for dispatch worldwide for test operations and adjustment of systems.
  • The company also offers other technical support such as periodic checking and adjustment of equipment and systems, and periodic servicing of equipment under maintenance agreements with respective client.
  • Technical consultation on thermal systems.

Test operation service
Test operation service

Checking and adjustment service
Checking and adjustment service